Install compression channel – Grain Systems Tanks PNEG-805 User Manual
Page 28
Advertising
7. Hopper Section Assembly
28
PNEG-805 36' Diameter 40°/45° NCHT Commercial Hopper Tanks
Install Compression Channel
After the compression angle weldments have been aligned, place the compression channels under the
compression angle weldments and fasten with 5/8"-11 x 2" bolts to the column attachment plates. Fasten
the inside and outside vertical compression angle segments to the channel, see
. Use the
supplied compression channel shim (CHT-1536) if necessary. Do not tighten bolts until hopper panels
are installed to allow alignment.
Figure 7D Compression Channel Erection
NOTE: Compression angle weldments not shown for clarity.
Ref #
Part #
Description
A
CHT-1536
Channel Shim
B
Fasten to column attachment plates
C
Fasten to compression angle members