7. Hopper Section Assembly

28

PNEG-805 36' Diameter 40°/45° NCHT Commercial Hopper Tanks

Install Compression Channel

After the compression angle weldments have been aligned, place the compression channels under the
compression angle weldments and fasten with 5/8"-11 x 2" bolts to the column attachment plates. Fasten
the inside and outside vertical compression angle segments to the channel, see

Figure 7D

. Use the

supplied compression channel shim (CHT-1536) if necessary. Do not tighten bolts until hopper panels
are installed to allow alignment.

Figure 7D Compression Channel Erection

NOTE: Compression angle weldments not shown for clarity.

Ref #

Part #

Description

A

CHT-1536

Channel Shim

B

Fasten to column attachment plates

C

Fasten to compression angle members