12. Stiffeners
50
PNEG-805 36' Diameter 40°/45° NCHT Commercial Hopper Tanks
2.66" Corrugation Commercial Stiffener Splice Details (Continued)
Figure 12G
NOTE: Install bolts in all bolt hole locations on stiffener splices.
Ref #
Description
A
Special Laminated Stiffener Splice Detail (SS-7427 Substituted for SS-6966)
B
Laminated Stiffener Assembly (SS-6929)
C
Laminated Stiffener Splice (SS-7427)
D
Use 3/8" x 1-1/2" Bin Bolt and 3/8" Hex Nut
E
Use 3/8" x 1-1/2" Flange Bolt and 3/8" Flange Nut
F
Bolting Detail for Laminated to Laminated Stiffener Connection
G
3/8" x 1-1/2" Flange Bolts and 3/8" Flange Nuts (30)