18 PNEG-1434 6", 8" and 10" Roof Augers
4. Assembly
Installing the Motor Mount Plate
A. Secure one (1) of the motor mount adjustment nuts and one (1) the motor mount adjustment
washers approximately 3/4" of the way down the motor mount adjuster’s threaded shaft.
B. Once the nut and washer is secure, slip the motor mount plate over the adjuster and align the pivot
holes with the pivot tube.
C. Slide the motor mount pivot rod through the pivot tube on the discharge tube.
D. When the pivot rod begins to extend through the pivot tube install the spacers, BETWEEN the
back plate and the inner face of the motor mount plate.
NOTE: The number of spacers will vary between each size of unloader.
Figure 4K
Figure 4L