Figure 8-24 Discharge Chute Hole Outline
D
Vertical center line
G
Horizontal center line
10.Separate the upper sidewall panel (I) from the lower sidewall panel (J).
11.Apply two beads of caulk to seal the discharge chute assembly to the sidewall panels, and insert the
discharge chute assembly (H) between the upper sidewall panel (I) and the lower sidewall panel (J).
NOTE: To ensure proper watershed, the discharge chute assembly (H) is installed behind the upper
sidewall panel (I) and in front of the lower sidewall panel (J).