Chapter 7: roof assembly – Grain Systems Tanks PNEG-4135A User Manual

Page 97

Advertising
background image

Chapter 7: Roof Assembly

Figure 7-16 Purlin location 8

A

Left-hand upper roof rafter (CTR-0548)

H

Purlin (CTR-0561)

B

1/2 x 1-3/4 in. flange bolt (S-10252)

I

1/2 in. flange nut (S-10253)

C

Right-hand upper roof rafter (CTR-0548)

J

Top X-brace (CTR-0580)

D

Right purlin clip (CTR-0316)

K

Bottom X-brace (CTR-0580)

E

Left purlin clip (CTR-0315)

L

1/2 x 1-3/4 in. flange bolt (S-10252)

F

1/2 x 1-3/4 in. flange bolt (S-10252)

M

1/2 in. flange nut (S-10253)

G

1/2 in. flange nut (S-10253)

Pneg-4135A 135 Ft Diameter 40-Series Bin

97

Advertising