PNEG-1459 L Series Operators

SELECT DATA LOG SAMPLE TIME

Notice the Modify button in the upper left hand side of the Dryer Status Chart. By touching this
button the sample time can be changed from 1 minute to 5, 10 or 15 minutes. Select the desired
sample time and touch Accept/Exit button to exit. Also notice that the chart can be cleared by
selecting the Clear Table button at the bottom.

OPTIONAL OPERATION SCREEN

An optional Operation Screen can be selected that shows a graph instead of the chart view.

Touching the

button at the bottom of the display will bring up the View Selec-

tion Window. Notice that you have four selections to choose from.

1.) Table View: This is the Default Operation Screen view (described on previous page).

2.) Graph View: This is the Optional Operation Screen view (shown below).

3.) Owners Manual: This option is described in greater detail on page 16.

4.) History: This option is described in greater detail on page 16.

5.) System Information: Touching this button will display the current software version your dryer
is running, and the time and date.

Touch the Graph View button then touch the
Exit button. The Optional Operation Screen
will appear. Notice that the Dryer Status Chart
and the Plenum(s) sections have been replaced
by the graph view (see image below). You can
choose what the graph will display by touching
any of the colored buttons under the graph (i.e.
Moisture In, Moisture Out, Dryer Temperature,
Grain Temperature In, Grain Temperature Out
and Meter Rolls).
Touching these buttons once will display them
on the graph, and touching them again will
remove them from the graph.

The Setup button will bring up the Graph
Setup Window and allow you to choose the
length of time (1, 2, 4 or 8 hours) for the
horizontal scale.