Dryer operation - intermediate moisture control – Grain Systems PNEG-1459 User Manual

Page 26

Advertising
background image

26

PNEG-1459 L Series Operators

DRYER OPERATION - INTERMEDIATE MOISTURE CONTROL

CONTINUOUS FLOW DRYING MODE USING INTERMEDIATE MOISTURE CONTROL

Full Heat-Continuous Flow Operation

This section begins with step 7 and it is assumed that steps 1 through 6 in the start-up procedure described on page 22 have been
completed.

7.

Touch the SETUP button at the bottom of the Dryer Operation screen. Once the Hardware Parameter screen is displayed

touch the DRYING MODE button. When the Select Drying Mode window appears touch the CONTINUOUS FLOW button to
select continuous flow drying mode. Then touch the EXIT button and return to the Hardware Parameter screen.

8.

Touch the M/C SETUP button. When the Moisture Control Selection window appears select the INTERMEDIATE :

REGULATION OF MOISTURE : 3 SPEED moisture control option. Now touch the EXTENDED SETUP button. When the
Set Unload Rate Limits window appears set the MAXIMUM Unloading Rate to a value lower than the rated BPH of any
auxiliary unloading equipment connected to the dryer. Next set the MINIMUM Unloading Rate. The minimum unloading rate
is used so that any auxiliary unloading equipment does run empty. By setting a minimum unloading rate the dryer unloading
system will never completely stop. This saves wear and tear on any auxiliary unloading equipment. Once the values have been
changed to the desired rate, press the “ACCEPT” button.

Intermediate: Regulation
of Moisture: 3 MR
Setpoints button

Extended Setup button:
Touching this button
will bring up the SET-
TING UNLOAD RATE
LIMITS window

Set Max. Unload Rate

Set Min. Unload Rate