15

Notes:

•

•

Max. lamp cable length of the "hot end" (higher potential to

ground): T5, T8: 1 m/T4: 0.5 m

•

•

Excessively long lamp cables cause the following problems:

- Poor radio interference suppression

- Uncertain lamp detection (not in T8)

- Poor synchronization of 2-lamp OSRAM DALI/DIM ECGs

•

Lay the lamp cables close together and close to the lamp

•

Lamp cables must not be laid in metal pipes and must not be
shielded cables

•

Guide the cables of the different lamp ends separately

•

In the case of multi-lamp OSRAM DALI/DIM ECGs, the cables to
the respective lamp ends must be of the same length to prevent
differences in the brightness

•

When dimming florescent lamps the maximum lamp voltage is
reached at the lowest dimmer setting (3 %-10 %) due to the nega-
tive current-voltage characteristic

Maximum line lengths between dimmable ECG
(QTi DALI/DIM) and lamps

Cold ends*

Hot ends*

1-lamp 21, 22

1-lamp 26, 27

2-lamp 21, 22, 23

2-lamp 24, 25, 26, 27

T5

1.5 m

1.0 m

T8

1.5 m (2 m HF DIM)

1.0 m (1.5 m HF DIM)

DULUX D/E, T/E

Every 0.5 m

Table 2: Maximum cable lengths between dimmable ECGs and
lamps

*

"Hot ends" are the lamp cables that have the highest potential to the
switching ground or protective ground. The other "cold ends" of the
lamp cables have a lower potential to ground.

Note:

•

Maximum capacitance of a filament cable pair to ground:

T5:

75

pF

T8/DL:

150

pF

•

Maximum capacitance between "hot" and "cold":

T5:

15

pF

T8:

30

pF