Manual – Xylem MJK 713 Open Channel Flowmeter User Manual

Page 15

Advertising
background image

15

Manual

US 3.10 713 Flow Converter 1210 - Sw 833062

MJK North America, Inc.
37 Sherwood Terrace, #126
Lake Bluff, Il 60044
Tel.: 847-482-8655
Fax: 847-482-8654
[email protected]
www.mjk.com

Cable extension
one of the most common faults on a MJK 713
installation is bad or faulty cable connections.
It is recommended to use a MJK connection box if the
sensor cable must be extended.

Ultrasonic sensor
the Shuttle

®

ultrasonic sensor are standard de-livered

with 40 ft of cable. the ultrasonic sensor can be deliv-
ered with up to 150 ft of cable on order, or the standard
40 ft cable can be extended to max. 150 ft.

The cable is a special low capacity cable,

so extensions should always be made with

the same type of cable.

the ultrasonic sensor cable has 5 wires with both color
code and number:

Number:

Color:

Designation:

1

Brown

Ultrasonic pulse

2

red

3

orange temperature compensation

4

Yellow

5

Black

Shield )*

)* This wire is connected to the cable shield.

the wires are mounted according to the terminal mark-
ings on the connection box PCB and on the MJK 713
respectively.

Cutting the cable

the cable is delivered with the wires stripped as shown
with the black wire (no. 5) soldered to the shield:

when the cable is cut, only 4 wires will appear:

When the cable has been cut, the shield

should be mounted in terminal 5 instead of

the black wire !

when the ultrasonic sensor is mounted and connected
correctly, the MJK 713 can be connected to the power
supply.
See section ‘Quick start’ on page 18.

To Shuttle

®

ultrasonic

sensor

To MJK 713
flow meter

Max.

150 ft !

MJK Connection
Box (NEMA 4X),
order no. 200590.

Advertising