Manual – Xylem MJK 713 Open Channel Flowmeter User Manual

Page 32

Advertising
background image

32

Manual

US 3.10 713 Flow Converter 1210 - Sw 833062

MJK North America, Inc.
37 Sherwood Terrace, #126
Lake Bluff, Il 60044
Tel.: 847-482-8655
Fax: 847-482-8654
[email protected]
www.mjk.com

Appendix C
Technical specifications

Dimensions and accessories

MJK 713

Flowmeter

Shuttle

®

Ultrasonic Sensor

Universal bracket

(order no. 200205)

Sensor bracket, standard

(order no. 200220)

Sensor bracket, short

(order no. 200219)

Flume mounting bracket

(Max. width 21.7 in: order no. 202020 /

max. width 37.4 in: order no. 202021).

3.78 “

Ultrasonic Sensor - one year warranty

Measuring range:

0 - 1 ft., 0 - 3 ft., 0 - 10 ft.

Frequency:

30 / 75 kHz

Beam angle:

3 / 7 °

temperature range:

- 5 to + 150 °F

Accuracy:

 ± 0.04 "

Deadband:

14 "

Dimensions:

Dia. 4.06 ", height 4.17 "

Materials:

vAloX (reg. tm of General electric Co.)

Cable:

Shielded, oil resistant PUr insulation, length 39 ft.

Can be extended to 150 ft. using MJK 690010 cable.

enclosure:

neMA 6P, waterproof, withstands submersion up to 30 ft.

Approvals:

FM Class 1 Division 1 Groups A-G

Ce en50081-1, en50082-1

Model 3400 Hydrostatic Level Transmitter - 1 year warranty

temperature range:

15 … 160 °F

temp. deviation, zero point: Better than ± 0.01 % / °F
temp. deviation, full range: Better than ± 0.005 % / °F
linearity / Stability:

Better than ± 0.5 % FS

Measurement accuracy:

Better than ± 0.1 % FS @ 50 to 85 °F

Better than ± 0.2 % FS @ full temperature range.

long time stability:

Better than ± 0.1% FS per year

Material:

Housing: PPS

Diaphragm: 99.9 % Al

2

o

3

Measurement cell packing: viton

®

Supply voltage:

10 - 30 v DC (12 - 30 v DC for cable lengths above 315 ft.)

output:

two-wire 4 - 20 mA (passive transmitter)

Cable:

2 × AwG 20, shielded, oil resistant PUr insulation

Cable length:

39 ft. longer cable lengths available, consult the factory.

enclosure:

neMA 6P,

withstands a static pressure equal to max. measuring range.

Approvals:

Ul

®

Class 1 Division 1 Groups A-D and AteX ex ia IIC t6

Ce en50081-1, en50082-1

Can be delivered with other cable lengths on request.

713 Series Open Channel Flowmeter

Measuring ranges:

0 - 1 ft., 0 - 3 ft., 0 - 10 ft. or custom ranges

Dimensions:

Height 7.28 “, width 9.45 “, depth 4.53 “

Power supply:

110 - 120 v AC, power consumption max. 10 w

temperature range:

- 5 to + 150 °F

Accuracy:

 0.2 % of adjusted range

Materials:

Polystyrene (housing and cover)

enclosure:

neMA 4X

Input signal:

either from ultrasonic sensor or from hydrostatic level

transmitter

or other (0)4 - 20 mA signal.

Digital outputs:

terminal 6 - 17:

relay no. 1-4, max. 250 v, max. 4
A resistive / max. 100 w inductive
load. Selectable as alarm, counter,
flow > 0 or sampler output.

terminal 19 - 20:

totalizer output (optocoupler),
max. 36 v AC/DC, 50 mA, one
shot,
programmable from 100 ms to
10 s.

Analog output:

terminal 21 - 22:

(0)4-20 mA, max. 500 ohm loop
resistance, galvanically isolated.

Calculation:

Standard formulas according to AStM standards and

US Department of the Interior.

optional formula Q = C × hx

or

10 point level to flow curve linearization.

Indication

2 × 24 character backlit lCD display for reading and

calibration.
Approvals:

Ul-cUl listed*,

file # 194021 Ul 508/c22: 2 no. 142-M1987

warranty:

1-year limited warranty

MJK 3400

Level Transmitter

5.31

1.26

Dia.1.97

MNPT

Advertising