Franklin Fueling Systems TS 550 evo Fuel Management System Programming Guide User Manual
Page 26

26
Dispenser Interface
The Dispenser Interface is used in the Reconciliation applications to communicate sales data from the dispensers to the
console.
Group Name
Parameter
Name
Parameter
Default
Description
Parameter Input
Dispenser Interface
Precision
Volume Precision
(3)
The number of digits to the right of the decimal point reported
by the dispensers.
0-6
Dispenser Volume
(Gross)
Select Gross if the dispenser volume is not temperature
compensated.
Gross / Net
Modify Volume Units
(No)
Allows changing the Dispenser Volume Units
Yes / No
Dispenser Volume
Units
(Gallons)
Select the units to measure dispenser volume
Liters
Gallons
Imp. Gallons
Grades
Number of Grades
(0)
The number of grades that are on site.
0 - 32
Name
(1)
Given name of Grade
abc#
Dispenser Interface Modules: DIM 1
Type
(Wayne)
The type of communication from the dispensers.
None
Gilbarco
Wayne
Tokheim
G Site
Bennett 515
Communication
(Currant Loop)
The communication protocol of the distribution box.
None
Current Loop
RS422 / 485
Tokheim STD
RS232 Duplex
RS232 RxD x 1
RS232 RxD x 2
Fueling Points
Number of fueling
points*
(0)
The number of possible fueling points on site
0 - 32
Number of hoses
(0)
The number of grades on this dispenser.
0 - 8
Hose #
(1)
Grade
Association
(Unknown)
The grade that is associated with the first hose you dispensed
from.
Select the correct
grade from the
Grades menu.
Position
(0)
The number that was detected from the Query function after a
dispense.
0 - 9
* Q The query function is used to determine the Position number from the dispensers.
C Will copy the Position numbers and Grade associations to all fueling points with the same number of hoses.
The copy and query functions are available only via the Web Browser Interface.
If using the console touch-screen, the “Auto-configure” button
will initiate the query function. ......(TBD)