DIM Programming

1.  For Web Browser programming capability, connect a computer to the T5 series tank gauge. (See programming 

section of this manual for connection information)

2.  From the 

Home screen, click Setup

3.  Click 

System Configuration, then Modules Expected.

Note:  The TS-550 evo can be built with the DIM module installed in the console. It is also possible to have DIM capability 

installed by a technician in the field. For information on installing the DIM module in the field, refer to DIM Module 

Installation Guide (part 000-2044)

4.  If the TS-550 evo was sent with DIM capability, verify that under 

Modules Expected, DIM is set to 1. 

5.  If the DIM module was installed in the field, you may need to set DIM to 1. Click on Edit in the upper right corner 

of the screen to allow the DIM setting to be changed to 1.

6.  Under Setup, click on 

Dispenser Interface / Precision.

7. Volume Precision refers to the number of digits to the right of the decimal. It will only affect how the information 

is displayed. Default is 3.

8. Dispenser Volume can be entered as Gross or Net.

a.  Gross-not temperature compensated (typical US)

b.  Net-temperature compensated (typical Canada)

9.  Under 

Dispenser Interface, click Dispenser Interface Modules

10. Type refers to the manufacturer of the Dispenser Distribution box. Select the type from the drop down list.

Some typical examples:

• Gilbarco-Universal D-Box (PA0261 Series)

• Wayne-Wayne/Dresser D-Box

• GSite-Gilbarco MOC G-Site and Passport Systems

• Tokheim-M98, M94 Power Center, 67 DBoxes