B&K Precision 9150-9153 - Manual User Manual

Page 20

Advertising
background image

20

Memory area

Number of groups/ area

Capacity/group

1

1

4KByte

2

2

2KByte

3

4

1KByte

4

8

512 Byte

Example: Group C can store 4 groups, each group has a maximum capacity of 1KByte.

The power supply executes a list in CONTINIOUS or Step mode. In CONTINIOUS mode, the power supply will

start executing the list once. As soon as a trigger signal is received, it will wait until the next trigger signal is

received.
Before you edit the list file, set the trigger source in the menu to “immediate”.

Example:

1) Press

Shift

+

MENU

2) Press up or down key to select “Config”, press

Enter

to confirm.

3) Press up or down key to select “Trig Source”, press

Enter

to confirm.

4) Press up or down key to select “Immediat”, press

Enter

to confirm.



Operation

Generate file:

1)

Press

2 cycles, continuous mode

Shift

+

Menu

into menu operation.

2)

VFD displays Config, press

▼to select List Set,press

Enter

to confirm.

3)

VFD displays Call ListFile, press

▼to select Edit ListFile, press

Enter

to confirm.

4)

VFD displays Continuous, press

Enter

to confirm.

5)

VFD displays Repeat, press

Enter

to confirm

6)

VFD displays Second, Select ms then press

Enter

to confirm

7)

VFD displays List Count= _, press numeric key or move the rotary knob, set number of cycles (in this

example, count is 2), press

Enter

to confirm.

8)

VFD displays 1th=*.****V, press numeric key or move the rotary knob, set the maximum

voltage, press

Enter

to confirm.

9)

VFD displays 1th=*.****A, press numeric key or move the rotary knob, set the maximum

current, press

Enter

to confirm.

10)

VFD displays 1th=*mS, press numeric key or move the rotary knob, set delay time, press

Enter

to confirm.

11)

VFD displays 2th=*.****V, press numeric key or move the rotary knob, set the maximum

voltage, press

Enter

to confirm.

12)

VFD displays 2th=*.****A, press numeric key or move the rotary knob, set the maximum

current, press

Enter

to confirm.

13)

VFD displays 2th=*mS, press numeric key or move the rotary knob, set delay time, press

Enter

to confirm.

14)

VFD display Store File_, press numeric key or move the rotary knob, set the register number (1 to 8)

,

press

Enter

to confirm.

15)

Press

Esc

two times to escape menu operation.


Execute file

Advertising
This manual is related to the following products: