B&K Precision 9150-9153 - Manual User Manual

Page 33

Advertising
background image

33

BK Precision manufacturer
XXXX product mode

XXXXXX product serial number

VX.XX software version number

For example: BK PRECISION,9120A,000004,V1.01

*OPC

When all commands sent to the instrument prior to this command have been executed, OPC of the standard event

status register will be set to 1.

Command syntax: *OPC

Parameter: None

Query syntax: *OPC?

Return parameter: <NR1>

*PSC

This command controls whether or not the power supply sends when it is reset.
1 OR ON: When power supply is reset, operation event enable register, query event enable register and

standard event status register are all

reset.


0 OR OFF: The data of status byte register, operation event enable register, quest event enable register and

standard event status enable register is stored in nonvolatile register, and is recalled when
power supply is reset.

Command syntax: *PSC <bool>

Parameter: 0|1|ON|OFF

Query syntax: *PSC?

Return parameter: 0|1

Reference command: *ESE *SRE STAT:OPER:ENAB STAT:QUES:ENAB

*RST

This command resets the power supply to its default setting.

CAL:SEC:STAT OFF
OUTP OFF, CURR MAX
VOLT:PROT:MAX
VOLT: MIN
TRIG:SOUR BUS
SYST:SENS OFF
PORT:MODE TRIG
RI:MODE OFF
DFI:SOUR OFF
VOLT:PROT:STAT OFF

Command syntax: *RST

Parameter: None

*SRE

This command can set the parameter of the status byte enable register. The value of this parameter determines

which bit value of the status byte register is 1 and the byte will enable RQS of status byte register is 1. The bit

definition of the status byte enable register is the same as the status byte register.

Command syntax: *SRE <NRf>

Parameter: 0~255

Reset value: Consult *PSC command

Example: *SRE 128

Query syntax: *SRE?

Return parameter: <NR1>

Advertising
This manual is related to the following products: