2 supplemental characteristics – B&K Precision 9150-9153 - Manual User Manual

Page 47

Advertising
background image

47

Load Regulation

±(%of output+offset)

Voltage

<0.01% + 0.5 mV

<0.01% + 1 mV

<0.01% + 1 mV

Current

<0.1% + 10 mA

<0.1% + 5 mA

<0.1% + 2 mA

Line Regulation

±(%of output+offset)

Voltage

<0.02% + 0.1 mV

<0.02% + 1 mV

<0.02% + 1 mV

Current

<0.1% + 1 mA

<0.01% + 1 mA

<0.01% + 0.1 mA

Programming resolution

Voltage

0.1 mV

1 mV

1 mV

Current

1 mA

1 mA

0.1 mA

Readback/Meter

resolution

Voltage

0.1 mV

0.1 mV

0.1 mV

Current

1 mA

0.1 mA

0.1 mA

Front Panel setting

resolution

Voltage

0.1 mV

0.5 mV

0.5 mV

Current

1 mA

1 mA

1 mA

Programming accuracy,

12 months (25 °C ± 5 °C)

±(%of output+offset)

Voltage

<0.02%+2 mV

<0.02%+6 mV

<0.02%+12 mV

Current

<0.1%+30 mA

<0.1%+15 mA

<0.05%+10 mA

Readback / Meter

accuracy

12months (25 °C ± 5 °C)

±(%of output+offset)

Voltage

<0.02%+1.5 mV

<0.02%+3 mV

<0.02%+6 mV

Current

<0.05%+15 mA

<0.05%+10 mA

<0.05%+5 mA

Ripple & Noise

(20 Hz ~20 MHz)

Voltage

≤0.005%+3

mVp-p

≤0.005%+3 mVp-p

≤0.005%+4

mVp-p

Current

15 mArms

5 mArms

3 mArms

Temperature coefficient,

(0 °C~40 °C)

±(%of output+offset)

Voltage

<0.02%+2 mV

<0.02%+5 mV

<0.02%+10 mV

Current

<0.1%+30 mA

<0.1%+15 mA

<0.05%+5 mA

Readback temperature,

coefficient,

±(%of output+offset)

Voltage

<0.02%+2 mV

<0.02%+5 mV

<0.02%+10 mV

Current

<0.1%+20 mA

≤0.05%+10 mA

≤0.05%+5 mA

DVM Accuracy

Voltage

0~12 V range: 0.02%+2 mV
0~40 V range: 0.02%+3 mV

DVM Resolution

Voltage

0~12 V range: 0.1 mV

0~40 V range: 1 mV

Ohm meter

m

Accuracy: 0.1%, for Voltage and Current >= 10% of FS (full

scale)

Accuracy: 0.3% for Voltage and Current = 3 to 10% of FS

Weight

net

63.9 lbs (29 kg)

Dimensions

WxHxD

429 mm × 88.2 mm × 458.9 mm

16.88(W) x 3.47(H) x 18.06(D) inch

*)

LVP: Limit Voltage Protection. Limits the voltage than can be set either via the front panel or remote control command.


NOTE:
Specifications and information are subject to change without notice. Please visit

www.bkprecision.com

for the most

current product information.








5.2 Supplemental Characteristics

State Storage Memory

50 user-configurable stored states


Recommended Calibration Interval