U5. specifications, 1 specifications, Specifications – B&K Precision 9150-9153 - Manual User Manual

Page 45

Advertising
background image

45

5.1 Specifications

5. Specifications


Models 9120A, 9121A and 9124

Parameter

9120A

9121A

9124

Output Ratings

( 0 °C~40 °C)

Voltage

0 - 32 V

0 - 20 V

0 - 72 V

Current

0 - 3 A

0 - 5 A

0 - 1.2 A

LVP*

0 - 33 V

0 - 21 V

0 - 73 V

Load Regulation

±(%of output+offset)

Voltage

<0.01%+2 mV

<0.01%+2 mV

Current

<0.05%+1 mA

<0.05%+0.3 mA

Line Regulation

±(%of output+offset)

Voltage

<0.01%+1 mV

<0.01%+1 mV

Current

<0.05%+0.1 mA

≤0.05%+0.05 mA

Programming resolution

Voltage

0.5 mV

2 mV

Current

0.1 mA

0.02 mA

Readback/Meter

resolution

Voltage

0.1 mV

0.1 mV

0.5 mV

Current

0.01 mA

0.05 mA

0.01 mA

Front Panel setting

resolution

Voltage

0.5 mV

2 mV

Current

0.1 mA

0.02 mA

Programming accuracy,

12 months (25 °C ± 5 °C)

±(%of output+offset)

Voltage

<0.03%+3 mV

≤0.03%+6 mV

Current

<0.05%+2 mA

≤0.05%+1 mA

Readback / Meter accuracy

12months (25 °C ± 5 °C)

±(%of output+offset)

Voltage

<0.02%+3 mV

≤0.02%+5 mV

Current

<0.05%+2 mA

≤0.05%+1 mA

Ripple & Noise

(20 Hz ~20 MHz)

Voltage

≤ 4 mV

p-p

≤ 3 mV

p-p

≤ 5 mV

p-p

Current

≤ 3 mArms

≤ 3 mArms

≤ 3 mArms

Temperature coefficient,

(0 °C~40 °C)

±(%of output+offset)

Voltage

<0.02%+3 mV

≤0.02%+5 mV

Current

<0.05%+2 mA

<0.05%+0.5 mA

Readback temperature,

coefficient,

±(%of output+offset)

Voltage

<0.02%+3 mV

≤0.02%+5 mV

Current

<0.05%+2 mA

≤0.05%+0.5 mA

Transient response

μs

< 150

μs for output to recover to within 75 mV following a

change from 100 mA to 1 A

DVM Accuracy

Voltage

0 - 12 V range: 0.02%+2 mV
0 - 40 V range: 0.02%+3 mV

DVM Resolution

Voltage

0 - 12 V range: 0.1 mV

0 - 40 V range: 1 mV

Ohm meter

m

Accuracy: 0.1%, for Voltage and Current >= 10% of FS

(full scale)

Accuracy: 0.3% for Voltage and Current = 3 to 10% of FS

Weight

net

19.8 lbs, (9 kg)

Dimensions

WxHxD

214.5 mm × 88.2 mm × 354.6 mm

8.45(W) x 3.47(H) x 13.9(D) inch

*)

LVP: Limit Voltage Protection. Limits the voltage than can be set either via the front panel or remote control command.


NOTE:
Specifications and information are subject to change without notice. Please visit

www.bkprecision.com

for the most

current product information.

Models 9122A, 9123A

Parameter

9122A

9123A

Advertising
This manual is related to the following products: