4.4 SCPI Command Description

Common IEEE488.2 Commands

*CLS

This command clears the following registers:
 Standard event status register
 Quest condition register
 Operation event register
 Status byte register
 Error code

Command syntax: *CLS

Parameter: None

*ESE

This command sets the parameter of the standard event enable register. The value determines which bit value of

the standard event register is set to 1. The ESB bit in of status byte register will change to 1 to reflect the

changes.

Command syntax: *ESE <NRf>

Parameter: 0~255

Reset value: Consult *PSC command

Example: *ESE 128

Query syntax: *ESE?

Return parameter: <NR1>

Reference command: *ESR? *PSC *STB?

Bit map of standard event status enable register

Bit position

7

6

5

4

3

2

1

0

Bit Name

PON Not used

CME

EXE

DDE

QYE

Not used

OPC

Bit Weight

128

32

16

8

4

PON Power-on
CME Command error
EXE Execution error

DDE Device-dependent error
QYE Query error
OPC Operation complete

*ESR?

This command queries the standard event status register. After executing this command, the standard event status

register is reset. The bit definition of the standard event status register is identical to the standard event status

enable register


Query syntax: *ESR?

Parameter: None

Return parameter: <NR1>

Reference command: *CLS *ESE *ESE? *OPC

*IDN?

This command reads information about the power supply. The return value contains 4 segments divided by a

comma.

Query syntax: *IDN?

Parameter: None

Return parameter: <AARD> segment description