4 Troubleshooting Guide

Below are some frequently asked questions and answers. Please check if any apply to your

power supply before contacting B&K Precision.

Q: I cannot power up the generator

-

Check that the power cord is securely connected to the AC input and there is live power

from your electrical AC outlet.

-

Verify that the AC power coming from the mains is the correct voltage. The generator

can accept a specific range of AC input voltages. Refer to section “2.1”.

Q: I cannot see any output out of the output terminals

-

Make sure that the Output buttons above channel 1 and/or channel 2 is lit. If not,

press it once. The backlight of these Output buttons indicates that the respective

channel’s output is enabled.

Q: I have connected my signal to an oscilloscope, but the amplitude is double of what I set

-

This is often because the impedance of the generator is not matched with the

oscilloscope. When the generator is set to 50 Ω impedance, connecting it directly to an

oscilloscope with a 1 MΩ input impedance will cause this to happen. To eliminate this

issue, connect a 50 Ω terminator to the input of the oscilloscope, then connect a BNC

cable between the generator and the terminator to have matching impedance.

Advertising