5.5 - Measurement result

After performing a balancing run, the out-of-balance values are displayed as well as arrows useful for positioning the
correction weight at the application point. After positioning and locking the wheel, apply the weight vertically at the
top. When the beep signal is enabled (

ACOUSTIC SIGNAL

), reaching of the correction position is accompanied

by a “beep”.
If the out-of-balance is less than the chosen threshold value, “0K” appears instead of the out-of-balance value to
indicate, on that particular side, that the wheel is in tolerance; the residual out-of-balance can be displayed by

pressing the button

, with an accuracy of 0.5 g (0.1 oz.)

The following buttons are enabled:

display of residual out-of-balance.

selection of correction mode (STATIC/DUAL SURFACE). When the mode is changed, the

unbalance values are recalculated automatically on the basis of the previous spin.

Simultaneous display of the dynamic+static unbalance can be enabled through the special

function in Setup (see par.

STATIC ALWAYS ENABLED

).

prints the balancing certifi cate (option)

: eccentricity measurement graph (OPTIONAL).

N.B

:

1. The symbol above the key is displayed in yellow if the fi rst harmonic eccentricity exceeds the

limit set in the setup parameters (

FIRST HARMONIC LIMIT

).

2. When this push button is held down for more than 1.5 seconds, eccentricity measurement is tempo-

rarily disenabled (enabled in GENERAL SETUP). To re-enable eccentricity measurement, press push

button [4] again for more than 1.5 seconds. Every time the machine is switched on, the status of eccen-

tricity measurement refl ects the settings in

GENERAL SETUP

.


unbalance split function enable

acquisition of new dimensions (

AUTOMATIC POSITION REPEATER

)

enable indication of the longitudinal position of the out-of-balance (

INDICATION OF EXACT

CORRECTION WEIGHT POSITION

)


selection of special functions

balancing

run.

SONAR STATUS RADIAL
ECC. (eccentricity)

SONAR STATUS
LATERAL ECC.
SONAR STATUS:

GREEN: in measuring position

RED: out of measuring range

N.B.: if the machine remains on this screen without being used for more than the time preset

in the Setup parameters (6), the screen automatically returns to the screen-saver.