4.6.2 - Opposite position

The normal balancing condition requires the correction weight to be applied at the top (12 o’clock) when the symbol
is displayed:

Apply the correction weight at the top (12 o’clock)

If OPPOSITE POSITION is enabled, the eventual application position for the bottom weight is also indicated next to
the positioning arrows to facilitate cleaning the rim and the relative application of adhesive weights. The symbol used
is:

Apply the correction weight at the bottom (6 o’clock)

6.6.6

- Static always enabled

Simultaneous display of the selected correction plane unbalance as well as STATIC unbalance can be enabled/disa

bled. The static frame can always be selected by pressing the

button from the measuring frame.

6.6.7 - Correction method

One of the three possible correction methods can be selected based on the specifi c requirements of the customer.

6.6.7.1 - Standard correction method

The wheel balancer considers the unbalance within tolerance when the value of each single plane is lower than the
tolerance set.

6.6.7.2 - External plane correction method

If correcting with adhesive weights, the unbalance is considered within tolerance when the recalculated external
plane weight (clip-on weights) is lower than the tolerance set.
Additional windows appear on the screen always displaying the residual external plane value (clip-on weight):