6.5 - General setup

(

Menu access diagram)

The Setup screen provides the user with many possibilities required for presetting the machine in relation to his own
requirements. Such settings remain unaltered even when the machine is switched off.

The following buttons are enabled:

: return to previous window

:

return to measurement screen

: for parameter selection.

6.5.1 - Language

This function allows selection of the language to be used for displaying descriptive and diagnostic messages regar-
ding machine operation.

6.5.2 - Screen-saver

If enabled (ON), if the machine is left unused on the initial frame, the screen saver automatically comes on. The
function can be disabled by setting “OFF”.

6.5.3 - Acoustic signal

When “ON” is selected, the acoustic signal (beep) is enabled in the following cases:

when any push button is pressed;
when dimensions are acquired in automatic mode;
when the correct angular position for weight application is reached in the Measurement screen;
when the correct angular position for weight application is reached in the Position Repeater screen.

6.5.4 - Setting the clock

Used to set date and time correctly. Follow the instructions on the screen.

6.5.5 - Guard opening during spin

Selecting “ON” the option to open the guard (when the motor is off) during the spin is enabled. If the guard is opened
when the motor is on, error 5 (guard open) is displayed.
Selecting “OFF”, error 5 (guard open) will always be signalled when the guard is opened.

6.5.6 - Automatic position repeater

Enables and disables the automatic position repeater control (

INDICATION OF EXACT CORRECTION WEIGHT

POSITION

)

6.5.7 - Options

6.5.7.1 - Eccentricity setup

Enables display of a menu where the following parameters can be set:

Side eccentricity measurement

enable

Enables/disenables lateral eccentricity measurement.

Radial eccentricity measurement

enable

Enables/disenables radial eccentricity measurement.

Eccentricity unit of measure

It is possible to select display of eccentricity measurements in mm or

inches.

First harmonic limit

The fi rst harmonic limit beyond which it is felt suitable to rotate the tyre

on the 180° rim. Recommended Limit = 1.2 mm.

Rim fi rst harmonic limit

Represents the fi rst harmonic limit of the rim below which it is not

considered appropriate to turn the tyre on the rim. Recommended limit:

0.3 mm.

Minimum correction limit

Represents the minimum correction limit obtainable below which it is

not considered appropriate to turn

the tyre on the rim. Recommended

limit: 0.8 mm.