8 - routine maintenance – CEMB USA C88 (A) User Manual

Page 39

Advertising
background image

I 0607 - 39

GB

Err.59

Radial and lateral Sonar readout error.
Lateral and radial Sonar values are insuffi -
cient for correct measurement of radial and
lateral eccentricity.

1.

Check points Err. 55

2.

Check points Err. 57

Err.65

Printer timeout

1. Check that a printer is present.
2. Check the code of the processor card.
3. Check the printer <-> processor card connection.
4. Run the printer test function.

Err.66

Printer buffer error

1.

Reset the printer.

2.

Repeat the print function.

8 - ROUTINE MAINTENANCE

8.1 - Scheduled maintenance

Switch off the machine from the mains before carrying out any operation.

8.2 - Replacing fuses

Remove the weight holder shelf to gain access to the power supply board where the 4 fuses are located (

Exploded Drawings). If fuses require replacement, use ones of the same current rating. If the fault persists, contact
Technical Service.

NONE OF THE OTHER MACHINE PARTS REQUIRE MAINTENANCE.