CEMB USA C88 (A) User Manual

Page 31

Advertising
background image

I 0607 - 31

GB

6.5.7.2 - Positioning

Automatic positioning enable of the outside or static side at the end of the spin.

6.5.7.3 - Enabling of serial output RS232C

This option enables/disables the sending of the measured unbalance and phase values to serial output RS232C.
Transmission speed

9600 baud

Data format

1 bit Start

8 bit Data

None

parity

1 bit Stop

At the end of each unbalancing measuring spin, the balancing machine transmits the data regarding the measured
unbalance. The items of data transmitted via serial line are in ASCII format and are separated between each other by
the <cr> character (0x0d).
Sending sequence is as follows:
- 00000 <cr>
- Value of correction weight, left side <cr>
- Correction phase, left side <cr>
- Value of correction weight, right side <cr>
- Correction phase, right side <cr>
The fi rst 5 zero bytes represents the start of transmission message. The correction values are expressed in grams, in
steps of .1 gram.
The phase values are expressed in degrees, in the range 0 ÷ 359.

6.5.7.4 - Printer enabling (optional)

Enable/disable printer and relative print options.

I

F

THE

OPTIONS

RS232

SERIAL

PORT

AND

PRINTER

ARE

ENABLED

AT

THE

SAME

TIME

,

BOTH

WILL

MALFUNCTION

.

6.5.7.5 - Wheel locking enable

Enables/disables wheel locking in the correction position (

WHEEL LOCKING

).

The possible options are:
OFF: disabled
ON: enabled
ALUS : enables wheel locking in position for the ALUS correction mode only.