TechnicalData

Type 2012

7.4

Operating conditions

7.4.1 Temperature ranges

actuator

size

[mm]

actuator

material

temperature ranges

medium (for ptfe

seal)

environment

1)

40 - 63

PA

–10 ... see “Fig. 5”

–10 ... see “Fig. 5”

80 - 125

PA

–10 ... +180 °C

–10 ... +60 °C

40 - 80

PPS

–10 ... +180 °C

+5 ... +140 °C

100 - 125

PPS

–10 ... +180 °C

+5 ... +90 °C

2)

Tab. 1: Temperature ranges

1)

If a pilot valve is used, the max. ambient temperature is + 55 °C.

Medium

temperature [°C]

Ambient

temperature

[°C]

100

120

140

160

180

200

70

60

50

40

30

20

∅ 63

∅ 50

∅ 40

Fig. 5: Temperature range of the maximum medium and ambient

temperature for PA actuators

2)

briefly up to max. +140 °C

7.4.2 pressure ranges

actuator

material

actuator size

[mm]

max. pilot pressure

[bar]

PA

40 - 100

10

125

7

PPS

40 - 100

10

125

7

Tab. 2: Maximum pilot pressure

medium and pilot pressure for control function a, flow direction
below the seat (standard)

Ori-

fice

maximum medium pressure / minimum pilot pressure

actuator size ø [mm]

40

50

63

80

100

125

10/15 15/4.0 16/3.9

20

6.5/4.0 11/3.9

16/4.5

25

5.2/3.9 11/4.5

16/5.0

32

6/4.5

14/5.0

16/4.4

40

4/4.5

9/5.0

12.5/4.4

16/3.2

50

2.5/4.5 6/5.0

7.2/4.4

10/3.2

65

12/5.6

Tab. 3: Medium and pilot pressure for CFA, standard