8 installation, 1 safety instructions 8.2 before installation – Burkert Type 2012 User Manual

Page 15

Advertising
background image

15

Installation

Type 2012

8

insTallaTiOn

8.1

safety instructions

Danger!

risk of injury from high pressure!

▶ Before loosening the lines and valves, turn off the pressure and

vent the lines.

Warning!

risk of injury from improper installation!

▶ Installation may be carried out by authorized technicians only and

with the appropriate tools!

risk of injury from unintentional activation of the system and
an uncontrolled restart!

▶ Secure system from unintentional activation.

▶ Following installation, ensure a controlled restart.
for control function i – danger if pilot pressure fails!
For control function I control and resetting occur pneumatically. If
the pressure fails, no defined position is reached.

▶ To ensure a controlled restart, first pressurize the device with pilot

pressure, then switch on the medium.

risk of injury from moving parts in the device!

▶ Do not reach into openings.

8.2

Before installation

Installation position: any, preferably with the actuator face up.
procedure:

→

Before connecting the valve, ensure the lines are flush.

→

Observe direction of flow.

8.2.1 preparatory work

→

Clean pipelines (sealing material, swarf, etc.).

devices with welded body
Remove the actuator from the valve body:

→

Clamp the valve body in a holding device.

note!

damage to the seat seal or the seat contour!

▶ When removing the actuator, ensure that the valve is in open

position.

→

Control function A:
pressurize the lower control air connection with compressed air
(6 bar): valve opens.

→

Using a suitable open-end wrench, place the wrench flat on the
tube.

→

Unscrew the actuator from the valve body.

english