Installation

7.2.3.

Adjusting limit switch contacts

The two upper limit switch contacts have been set to 0 – 90° at the factory.

Removing position indicator and hood

1

Figure 8:

Removing glass hood

Figure 9:

Removing position
indicator

Figure 10:

Removing hood

Procedure:

Remove glass hood of the position indicator 1 including the sealing ring by loosening the four fastening screws
and remove the glass hood (see “Figure 8”).

Remove position indicator (see “Figure 9”).

Remove hood 2 by loosening the four fastening screws 3 (see “Figure 10”).

Adjusting cams for limit switch contacts

Cam

Key

Adjustment travel

Cam

Key

Adjustment travel

Figure 11:

Adjusting limit switch clockwise

Figure 12:

Adjusting limit switch anti-clockwise

Procedure:

Adjust the two upper cams with a suitable key (see “Figure 11” and “Figure 12” ).

On completion of the adjustment work, re-attach the hood 3, the position indicator, the seal and the glass hood 1.