Appendix B, SCA File Format - SCA Format

61179605L5-5B

B-5

7

Annex

0 = A
1 = B
2 = A/B

8

LineProbing

0 = Disabled
1 = Enabled Current Condition
2 = Enabled Worst Case

9

Repeater Mode

0 = Terminator
1 = Repeater

A

M-pair Mode

0 = 2-wire
1 = 4-wire
2 = Mpair

B

Number of Pairs (Mpair mode
only)

2 pairs ONLY

C

Valid Data Slots (Mpair mode
only)

Bit-wise representation of the ports to be physically
bonded:

bit 0 - pair 1
bit 1 - pair 2
bit 2 - pair 3 (NOT VALID)
bit 3 - pair 4 (NOT VALID)

D

Min Line Rate

N = 3 to 36, where rate = N × 64k + 8k

E

Max Line Rate

N = 3 to 36, where rate = N × 64k + 8k

F

Current Line Rate

N = 3 to 36, where rate = N × 64k + 8k

10

Min Sub Rate

N = 0 to 7, where rate = Line Rate + (N × 8k)

11

Max Sub Rate

N = 0 to 7, where rate = Line Rate + (N × 8k)

12

PMMS Margin CC

–10dB to 20dB

13

PMMS Margin WC

–10dB to 20dB

14

Clock Mode

0 = Plesio
1 = Plesio w/Reference
2 = Sync
3 = Sync Hybrid

15

Framing Mode

0 = Frame Plesio
1 = Frame Sync
2 = Frame Transparent

16

F-bit notifications

bit 3 = segment defect: 1 = normal, 0 = segd alarm
bit 2 = power status: 1 = normal, 0 = rem loss of power
bit 1 = segment anomaly: 1 = normal, 0 = sega alarm
bit 0 = loss of signal: 1 = normal, 0 = loss of signal

Table B-5. LocSTULineProvisioning (Continued)

Column

Option

Values