Sca file example – ADTRAN Total Access 1240 User Manual

Page 142

Advertising
background image

Total Access 1240 Installation and Maintenance Practice

B-6

61179605L5-5B

SCA FILE EXAMPLE

Figure B-1

provides an example of an SCA file.

17

Performance Primitive
Notifications

bit 7 = segment anomaly
bit 6 = CRC anomaly
bit 5 = segment defect
bit 4 = loss of sync word defect
bit 3 = SNR margin defect
bit 2 = loop attenuation defect
bit 1 = loss of sync word failure
bit 0 = tip/ring reversal

18

SHDSL ES 15 Minute Alarm
Threshold

0 = Disabled
1 to 900 = threshold in seconds

19

SHDSL SES 15 Minute Alarm
Threshold

0 = Disabled
1 to 900 = threshold in seconds

1A

SHDSL UAS 15 Minute Alarm
Threshold

0 = Disabled
1 to 900 = threshold in seconds

1B

SHDSL CVC 15 Minute Alarm
Threshold

0 = Disabled
1 to 65535 = threshold in seconds

1C

SHDSL LOSWS 15 Minute
Alarm Threshold

0 = Disabled
1 to 900 = threshold in seconds

1D

Line Rate Control

0 = STU-C
1 = STU-R

1E

SHDSL OS 15 Minute Alarm
Threshold

0 = Disabled
1 to 900 = threshold in seconds

1F

Outage Auto-Retrain

0 = Disabled
1 = Enabled

20 - 27

Reserved Options for future use

Table B-5. LocSTULineProvisioning (Continued)