FAAC Model S418 Swing Gate Operator

Fig. 15

Fig. 16

Fig. 17

6. Secure the operator to the rear bracket using the

appropriate bolt supplied, as indicated in Figure 15.

7. Bring the leaf of the gate to the close position.

8. Bring the operator, together with the related bracket,

alongside the leaf.

9. Check that the operator is horizontal using a level,

as indicated in Figure 16, and temporarily secure it

with clamps or two welding points.

The axis of the securing holes of the front bracket must

be aligned with the axis of the securing holes of the rear

bracket, see Figure 17.

If the structure of the gate does not permit reliable

mounting, the structure of the gate must be reinforced

to provide a solid supporting base.

10. Prepare the operator for manual operation, see

Section 5, and move the leaf manually, checking that

it completes the entire opening operation required,

stopping at the mechanical stops.

If, during the test, the operator hits the leaf of the

gate, value

E may be increased, see Figure 4, up to

a maximum of 4

½ inches, using appropriate spacers

placed between the front bracket and the leaf of the

gate.

11. Perform any corrective measures necessary and

repeat the procedures from Step 9.

12. Permanently secure the front bracket, using a

suitable securing system as indicated in Figure 18.

If it is decided to weld the bracket directly onto the

leaf, the operator must be released temporarily. Wait

for the bracket to cool before reattaching the

operator.

Fig. 18

3.5

WIRING THE OPERATOR

The operator is supplied with the cable already connected.

If the cable has to be replaced, install a cable rated for

outdoor use.

3.6

MECHANICAL STOPS

The S418 operator is supplied with mechanical stops

on opening and closing as standard. These may be

used in place of mechanical stop-points for the leaf. For

adjustment of the stops, proceed as follows:

3.6.1 Mechanical Stop at Opening

1. Prepare the operator for manual operation, see

Section 5.

2. Manually move the leaf into its opening position.

3. Loosen the securing screw, Figure 19 Ref. 1. The

screw does not need to be completely removed.