Controlled Products Systems Group 104301 User Manual

Page 20

Advertising
background image

6

TR 3

– SPEED ADJUSTMENT FOR MOTOR1 AND MOTOR 2

Turn clockwise to increase the opening and closing speed

TR 4

– SENSITIVITY ADJUSTEMENT FOR OBSTACLE DETECTION FOR MOTOR 1 AND MOTOR 2

Turn clockwise to increase the sensitivity for obstacle detection.

With this trimmer you can adjust the reaction time for the board to invert the motion of the gate in case of

obstacle detection, or the complete stop in case the board is in the positive stop detection zone.

If an obstacle is detected during the gate movement the board will invert the motor rotation until the gate goes

back to the original starting position. If in the successive movement an obstacle is detected again the board

will be put in alarm mode and won’t take any more commands until the STOP input is activated (Alarm Reset)

or power is cycled

TR 5

– PAUSE TIME ADJUSTMENT ( 0 - 4 min. )

Turn clockwise to increase the pause time.

TR6

- CLOSING DELAY OF LEAF 1 OVER LEAF 2 ADJUSTMENT ( 0 - 15 sec )

Turn clockwise to increase the delay

TR1

– FORCE ADJUSTMENT MOTOR 1

Turn clockwise to increase the opening and closing force

1 min

2 min

3 min

4 min

0 sec

30 sec

TR 2

– FORCE ADJUSTEMENT MOTOR 2

Turn clockwise to increase the opening and closing force

4.2 ADJUSTING TRIMMERS

Dip switches DS1: 1 to 3 need to

be set for an operating mode with

PAUSE time for this adjustment

to have any effect

A8

E024U CONTROL BOARD