BOARD SETUP

DS 1: SW 4 to SW 12

OPENING DELAY

SW 4

The opening of leaf 2 is delayed after the opening of leaf 1. This is to avoid

that the gate’s leafs interfere with each other during the initial part of the

movement. In case there is only one leaf is has no effect.

0 sec (default)

OFF

2 sec

ON

REVERSE AND LAST STROKE

SW 5

If active, before opening, while the gate is closed, the motors thrust to

close for 2 s to facilitate the release of the electric lock. At closing the

motors are activated for a final stroke after slowdown to facilitate locking

of the electric lock.

inactive (default)

OFF

active

ON

MAX THRUST AT STARTUP

SW 6

With this fuction active the motors work at maximum force at startup

(regardless of the force setting) during the initial phase of the movement.

Useful for heavy leafs

inactive (default)

OFF

active for 3 sec

ON

AUTOMATIC OPENING IN CASE OF

POWER FAILURE

SW 7

If active and with the optional backup battery installed, the board will

open the gate after one minute from the power failure and keep it open.

Within the minute wait it’s always possible to open and close the gate

with a command. If the logic used has a pause time the board will close

the gate when the power comes back.

inactive (default)

OFF

active

ON

CLOSING SAFETY LOGIC

SW 8

With this function you can choose the behaviour of the closing safety. With

SW8 OFF the gate movement will be reversed as soon as the safety is active,

with SW8 ON the gate will stop when the safety is active and it will reverse

only when the safety is deactivated again.

immediate reverse (default)

OFF

reverse when cleared

ON

PREFLASHING

SW 9

This function activates the flashing lamp for 5s before the movement of

the gate

inactive (default)

OFF

active for 5 sec

ON

EXTRA SENSITIVITY TO
OBSTACLE DETECTION

SW 10

If active this function allows to have an immediate reverse in case the

gate hits a rigid obstacle, while keeping the motor active in case of a

gradual increment of resistance, like with wind pressure on the gate or

increased friction

inactive (default)

OFF

active

ON

ORANGE TERMINAL FUNCTION

SW 11

If OFF after the second consecutive obstacle detection this output is

activated until the STOP contact is open or the power is cycled

if ON the output can be connected to a warning lamp.

NOTE: for UL325 compliance this switch must be left OFF

Audio Alarm (default)

OFF

Warning Lamp

ON

OUT FUNCTION (pin 9)

max 100mA

SW 12

if OFF: use pin 9 as power supply negative for a warning lamp. The

lamp will be active during opening, pause and stop. Flashing during

close, off when the gate is closed
If ON: use pin 9 as power supply negative for the safety photocells.

Before any movement the board will check for the presence of the

safety photocells. If the test fails the gate will not move.

Lamp

OFF

Photocells FAIL SAFE active

ON

4.3 DIP SWITCH DS1 SETTINGS FOR BOARD SETUP