Installation, Technical specifications – Controlled Products Systems Group 104301 User Manual

Page 7

Advertising
background image

7

FAAC Model S418 Swing Gate Operator

3. INSTALLATION

Technical Specifications

S418

Power Supply (VDC)

24

Nominal Power (W)

35

Absorbed Current (A)

1.5

Maximum Thrust Force (lbf)

405

Stroke (inches)

13 3/4 1

Cycles per day at 68 °F (approx)

80

Class of operation

Residential

Rod speed (inches/sec)

0.7

Maximum Size of Leaf (feet)

12

Ambient Operating Temperature (°F)

-4 to 131

Operator Weight (lbs)

13.2

Protection Class

IP54

1 If you do not use the mechanical stops on opening and

closing, the operator stroke increases to 15 1/4 inches.

2.

TECHNICAL SPECIFICATIONS

3.2

PRELIMINARY CHECKS

The structure of the gate directly influences the reliability

and safety of the automated system. To ensure correct

operation, the structure of the existing gate, or that to be

fitted, must have the following characteristics:
• The length of leaf must conform to what is shown in the

technical characteristics of the operator (Section 2).

• The structure of the leaves must be sturdy and rigid,

suitable for an automated system.

• There must be regular and uniform movement of the

leaves, with no friction or sticking along their entire

movement.

• Hinges must be suitably sturdy and in good condition.

It is recommended that any metalwork operations

should be performed prior to installing the automated

system.

3.1

ELECTRICAL SETUP

When laying electrical cables, use conduits with adequate

rigidity and/or flexibility.

To avoid any type of interference, always separate low-

voltage accessories and command connection wiring from

power supply cables, use separate sheaths.

Fig. 3

Part

Description

Cables

1

Operators

2 x AWG 14 (max 30’)

AWG 12 (max 50’)

AWG 10 (max 100’)

2

Control Unit

3 x AWG 14 (AC Power)

3

TX Photocells

4 x AWG 20

4

RX Photocells

2 x AWG 20

5

Key Selector

2 x AWG 20 (1 contact)

6

Flashing Lamp

2 x AWG 14

7

External Antenna

Coaxial Cable

8

Mechanical Stops

Dimensions in Inches

3.3

INSTALLATION DIMENSIONS

Determine the assembly position of the operator, referring to

Figure 4 and relative table. It is a good idea at this stage to

choose whether or not you want to use the built in mechanical

positive stops; eliminating the mechanical stops increases the

working stroke of the operator and values

A and B must be

changed.

Fig. 4

a

A

B C 1 D 2 Z 3 L

E 3

With both

stops

90°

6½ 6½ 13 3½

3 27

4⅛

6⅞ 6⅞ 13¾ 3½ 3⅛ 27

4⅛

110°

6

6 13⅜ 3⅛ 2¾ 27

4⅛

With open

stop

90°

6⅞ 6½ 13⅜ 4

3 28

4⅛

7

7 14⅛ 4

3⅛ 28

4⅛

110° 6¼ 6¼ 14⅛ 3½ 2¾ 28

4⅛

With no stops

90°

7

7 14⅛ 4

2¾ 28

4⅛

110° 6⅝ 6⅝ 15

4

2¾ 28

4⅛

1 Working stroke of the operator.

2 Maximum value.

3 Minimum value.

Advertising