Led error display, Time learning (set-up) – Controlled Products Systems Group 104301 User Manual

Page 24

Advertising
background image

WARNING: If the time learning setup is done automatically then

the slow down points are set by the board on his own

Move the leafs to the mid position

Very important for a good result

1. Press and hold the SETUP button until the SETUP LED

lights up, wait about 3 sec. until it turns off and then release

it immediately. NOTE: If you wait too long to release it the

manual set-up will start. The LED will blink during the setup

procedure

2. Leaf 2 (if present) starts to move slowly in closing direction,

stopping when it reaches the mechanical stop or FCC2.

3. Leaf 1 begins to move slowly in closing direction, stopping

when it reaches the mechanical stop, or FCC1.

4. Leaf 1 starts to move slowly in opening direction, followed

by leaf 2 (if present)

still slowly

.

5. When they both reach the open mechanical stop or FCA1 and

FCA2 they stop and reverse, leaf 2 (if present) automatically

starts closing at full speed followed by leaf 1.

After powering up the board for the first time or when the board

will need it the setup LED will blink at a slow frequency to indicate

that the setup procedure to learn the running times is needed.

The setup can be redone at any time by pressing and holding

the setup button as indicated below.

After the setup first movement, if the leafs are opening instead

of closing you need to reverse the wires going to the motor that

moves in the wrong direction

LED ERROR DISPLAY

NUMBER OF

FLASHES

ERROR CONDITION

SOLUTION

1

OBSTACLE DETECTION

Remove the obstacle

2

BOARD IN SLEEP MODE

(Slow blinking means that the automatic open

in case of power failure function is active)

Verify the presence of AC power

3

MOTOR 1 FAILURE

Replace motor 1

4

MOTOR 2 FAILURE

Replace motor 2

5

ENCODER on motor 1 or motor 2 broken or

wiring error

Verify the encoder wiring and LED status. If they are correct replace

the encoder

6

FAIL SAFE FAILED

Verify the photocells wiring and alignement

7

BOARD THERMAL PROTECTION ACTIVE

Turn off the board and wait until the components cool down

8

MAX RUN TIME REACHED

WITHOUT FINDING THE

POSITIVE STOP (10 min. )

- Verify that the operator manual release is not engaged

- Verify that the board recognizes the mechanical stop, in

case redo the setup procedure

The diagnostic LED shows only one error condition at a time, with the priority of the below table. In case there is more

than one error once one is eliminated the LED will show the next

6. When they reach the close mechanical stop or FCC1 and

FCC2 both leafs stop and leaf 1 restarts automatically ope-

ning at full speed followed by leaf 2 (if present).

7. If you selected an automatic logic the board will wait for the

pause time and then closes the gate automatically. Other-

wise you have to give an OPEN command to close the gate.

WARNING: If the manual time learning setup is done then

the slow down points must be set by the installer during the

procedure

Move the leafs to the mid position

Very important for a good result

1. Press and hold the SETUP button until the SETUP LED

lights up, keep it pressed for about 3 sec. until it turns off and

keep it pressed more until the leaf 2 (if present) starts mo-

ving slowly. The LED will blink during the setup procedure

2. Leaf 2 will move in closing direction until it reaches the

mechanical stop or FCC2

3. Leaf 1 starts moving slowly until it reaches the mechanical

stop or FCC1

4. Leaf 1 starts moving in opening direction at the set speed

(trimmer speed).

5. At the point where you want the slowdown to start give an

OPEN A command with the push button or the remote that

is already stored in memory. Leaf 1 starts to slow down

and stops when it reaches the mechanical stop or FCA1.

6. Leaf 2 starts moving in opening direction at the set speed

(trimmer speed)

6. TIME LEARNING (SET-UP)

6.1 AUTOMATIC TIME LEARNING

6.2 MANUAL TIME LEARNING

A12

E024U CONTROL BOARD

Advertising