FSW
STP CL OP

FSW
STP CL OP

Connection of two pairs of closing photocells

Connection of a pair of closing photocells, a pair of opening photcells and a pair of opening/closing photocells

Other optional safety devices to connect in series

Fig. A7

Fig. A8

To use the FAIL-SAFE mode connect the negative power supply of the transmitters to OUT (pin 9), and

set dip-switch 11 and 12 to ON on DS1

When using the FAIL-SAFE mode also the safety inputs not used (FSW CL , FSW OP) must be connected

to OUT (pin No. 9)

To use the FAIL-SAFE mode connect the negative power supply of the transmitters to OUT (pin 9),

and set dip-switch 11 and 12 to ON on DS1

RX= Photocell Receiver

TX= Ptotocell Transmitter

CL= Closing

OP= Opening

RX= Photocell Receiver

TX= Ptotocell Transmitter

CL= Closing

OP= Opening

A5

E024U CONTROL BOARD