To use the FAIL-SAFE mode connect the negative power supply of the transmitters to OUT (pin 9), and set dip-

switch 11 and 12 to ON on DS1

Connection of a pair of closing photocells and a pair of opening photocells

Fig. A9

Connection of no safety or stop devices
(NOT RECOMMENDED)

Connection of one pair of opening photocells

Other optional safety devices to

connect in series

Fig. A10

Fig. A11

Fig. A12

T

o use the FAIL-SAFE mode connect the ne-

gative power supply of the transmitters to OUT

(pin 9), and set dip-switch 11 and 12 to ON on

DS1

When using the FAIL-SAFE mode also the

safety inputs not used (FSW CL , FSW OP)

must be connected to OUT (pin No. 9)

RX= Photocell Receiver

TX= Ptotocell Transmitter

CL= Closing

OP= Opening

Connection of a generic closing safety device and a generic
open safety device

A6

E024U CONTROL BOARD