background image

4. PROGRAMMING

OPERATING LOGIC

DS 1: SW 1 - SW 2 - SW 3

LOGIC

SW

1

SW

2

SW

3

PAUSE

TIME

DESCRIPTION

E (default)

Semiautomatic

OFF OFF OFF

NO

One command opens, the next one closes. A command du-

ring opening stops the gate

A

Automatic

ON

ON

ON

0 - 4

min

One command opens, waits for the pause time an then closes

automatically

S

Security

OFF OFF ON

0-4

min

One command opens, waits for the pause time and then clo-

ses automatically. If the closing safety is activated or another

command is given during the pause time it closes

EP

Semiautomatic

step by step

OFF ON OFF

NO

One command opens, the next one closes. During the move-

ment a command stops the gate

AP

Automatic

step by step

OFF ON

ON

0-4

min

One command opens, waits for the pause time and then clo-

ses automatically. A command during the pause time holds

the gate open

SP

Security

step by step

ON OFF OFF

0-4

min

One command opens, waits for the pause time and then

closes automatically. If the closing safety is activated during

pause time the gate closes in 5 s. A command during pause

time holds open the gate

B

Manned Pulsed

ON OFF ON

NO

An open A command opens the gate, an open B command

closes the gate

C

Manned Constant

ON

ON OFF

NO

Holding open A active opens the gate, holding Open B active

closes the gate

For more details on the operating logics please refer to Chapter 12 - Function Logics

4.1 DIP SWITCH DS1 SETTINGS FOR OPERATING LOGIC

A7

E024U CONTROL BOARD