Last 1812, Maximum 1812 wiring configuration – DoorKing 1812 Access Plus User Manual

Page 18

Advertising
background image

1812-162-M-1-12

16

J1

1
2
3
4
5
6
7
8

J4

J1

1
2
3
4
5
6
7
8

J4

Note: Each 1812 must be
programmed for MULTIPLE
SYSTEMS, have a unique
ATTENTION NUMBER (See
2.4.2 and 2.4.3) and have a
unique MASTER CODE (See
2.1).

Note: The 1812 that is
connected directly to the
homeowner’s phones (1st
1812) must have its
“Number of Rings”
programming set for 1 less
than the other 1812s wired
in series (See 2.4.9).

EARTH

GND

1

CENTRAL

OFFICE

PHONE

IN

PHONE

OUT

HOME

2

3

4

5

6

7

8

SW1

ENTRY

BY-PASS

1875-010

1

CENTRAL

OFFICE

EARTH

GND

PHONE

IN

PHONE

OUT

HOME

2

3

4

5

6

7

8

SW1

ENTRY

BY-PASS

1875-010

Be sure to properly ground ALL
1812s. See page 13 for
acceptable grounding sources.

Relay 2 to Access Control Device

To 16.5 VAC Supplied Transformer

To 16.5 VAC Supplied Transformer

Relay 1 to Access Control Device

Relay 2 to Access Control Device

Relay 1 to Access Control Device

1.8 Wire Multiple 1812s: Telco/Internet - Telephone Mode

Cat5e

Cat5e

Cat5e

Cat5e

Cat5e

By-Pass Board

The By-Pass board is NOT optional and must be
installed as part of multiple 1812s “Telephone Mode”
system.
See page 11 for complete information.
Multiple 1812s:
PHONE IN #3 connects to 1st 1812 Main Term #1.
PHONE IN #4 connects to 1st 1812 Main Term #2.
PHONE OUT #5 connects to Last 1812 Main Term #5.
PHONE OUT #6 connects to Last 1812 Main Term #4.

J1

Main

Terminal

1970-010

18

17

16

Com

15

N.C.

14

N.O.

13

Com

12

N.C.

11

N.O.

10

9

8

7

6

5

RING

4

TIP

3

GND

2

TIP

1

RING

16.5
VAC

Relay 1

Relay 2

Power

J1

Main

Terminal

1970-010

18

17

16

Com

15

N.C.

14

N.O.

13

Com

12

N.C.

11

N.O.

10

9

8

7

6

5

RING

4

TIP

3

GND

2

TIP

1

RING

16.5
VAC

Relay 1

Relay 2

Power

Last 1812

See previous

2 pages for

wiring and

information.

See previous

2 pages for

wiring and

information.

See previous 2

pages for more

information

about Telco OR
Internet wiring.

Use the previous 2 page’s wiring diagrams and
information to wire multiple 1812s except for
the By-Pass board’s “PHONE IN” and “PHONE
OUT” terminal connections. Up to five (5) 1812s
may be wired in series
to the By-Pass board
using the method shown on this page: 1st
1812’s PHONE OUT to 2nd 1812’s PHONE IN;
2nd 1812’s PHONE OUT to 3rd 1812’s PHONE
IN, etc. Connect the last 1812’s PHONE OUT
back to By-Pass board’s PHONE OUT.

1st 1812

Check Polarity of Telephone Line

See previous 2 pages for information.

Be sure to properly ground ALL
1812s. See page 13 for
acceptable grounding sources.

Ground 12 AWG Min.

Phone Out

Phone Out

Phone In

Phone Out

Phone In

Phone Out

Phone In

Phone Out

Phone In

Phone In

Phone In

Phone Out

Ground 12 AWG Min.

77

8

9

4

5

6

0

1st 1812

Phone Mode

(E.g.: 5 Rings)

2nd 1812

Phone Mode

(E.g.: 6 Rings)

3rd 1812

Phone Mode

(E.g.: 6 Rings)

4th 1812

Phone Mode

(E.g.: 6 Rings)

5th 1812

Phone Mode

(E.g.: 6 Rings)

7

8

9

4

5

6

0

7

8

9

4

5

6

0

7

8

9

4

5

6

0

7

8

9

4

5

6

0

Phone

Company

Internet

Homeowner’s Phones

(LAN/Cordless)

Maximum 1812 Wiring Configuration

Ground

12 AWG Min.

Phone In

(1-2)

Phone Out

(4-5)

Phone In

(1-2)

Phone Out

(4-5)

TIP

TIP

TIP

RING

RING

RING

TIP

RING

OR

Fiber / V

olP

Device

Phone

Jack

Phone

Jack

Homeowner’s

LAN/Cordless Phones

TIP

Older Lines

Green Wire (+)

Older Lines
Red Wire (-)

RING

OV

OV

Advertising