1 phone mode or intercom mode, 2 single or multiple systems, 3 system attention number – DoorKing 1812 Access Plus User Manual

Page 34: 4 single or double ring

Advertising
background image

1812-162-M-1-12

32

2.4.1 Phone Mode or Intercom Mode

Factory setting is 1 (Phone Mode).

The 1812 is normally connected in series with a resident’s incoming phone line, which supplies a constant source of DC
voltage. When the 1812 is connected in this manner, program the unit for PHONE mode.
If the 1812 is to be connected to an open C.O. (Central Office) port on a key type telephone system, or if the 1812 is
connected directly to a telephone without a C.O. line, program the unit for INTERCOM mode. When programmed in
intercom mode, the 1812 will supply the constant DC voltage necessary for operation and will disconnect the PHONE-IN
terminals 1 and 2 from the circuit board since these are not used in intercom mode.
If the 1812 is programmed for the intercom mode, the call forward and preprogrammed dial-out phone number (Directory
Codes) features will not work.

1. Press

*

0 6 and enter the MASTER CODE. [

*

0 6 _ _ _ _ (beep)]

2. Press 1

*

for phone mode OR press 0

*

for intercom mode. [ _

*

(beep)]

3. Press 0 # TOGETHER to end. [0 # (beeeeeep)]

2.4.2 Single or Multiple Systems

Factory setting is 1 (Single System).

Set for single if the 1812 is the only unit connected to the phone line, or set to multiple if more than one 1812 is connected
to the phone line.

1. Press

*

6 1 and enter the MASTER CODE. [

*

6 1 _ _ _ _ (beep)]

2. Press 1

*

for a single system OR press 0

*

for multiple systems. [ _

*

(beep)]

3. Press 0 # TOGETHER to end. [0 # (beeeeeep)]

2.4.3 System Attention Number

Factory setting is 7.

The system attention number is the number that the 1812 responds to when called from the residence. If more than one
1812 is sharing the phone line, be sure the attention number to each unit is programmed with a unique attention number.

1. Press

*

6 2 and enter the MASTER CODE. [

*

6 2 _ _ _ _ (beep)]

2. Enter a single digit attention number (0-9), then press

*

. [ _

*

(beep)]

3. Press 0 # TOGETHER to end. [0 # (beeeeeep)]

2.4.4 Single or Double Ring

Factory setting is 1 (Double Ring).

Setting this for a double ring provides a unique ring so that a call from the 1812 is easily identified, or the ring can be set to
the standard single long ring.

1. Press

*

6 3 and enter the MASTER CODE. [

*

6 3 _ _ _ _ (beep)]

2. Press 1

*

for a double ring OR press 0

*

for a single ring. [ _

*

(beep)]

3. Press 0 # TOGETHER to end. [0 # (beeeeeep)]

2.4.5 Number of Home Phone Rings Before 1812 Hangs Up

Factory setting is 05 (5 Rings).

When the CALL button on the 1812 is pushed, this programming sequence sets the number of unanswered rings to the
homeowner’s phone before the 1812 hangs up.

1. Press

*

6 4 and enter the MASTER CODE. [

*

6 4 _ _ _ _ (beep)]

2. Enter the number of rings before 1812 hangs up (01-99), then press

*

. [ _ _

*

(beep)]

3. Press 0 # TOGETHER to end. [0 # (beeeeeep)]

Advertising