1812-162-M-1-12

22

Relay 2

Relay 1

Relay 2

Relay 1

Relay 2

Relay 1

Relay 2

Relay 1

Relay 2

Relay 1

Each 1812 has
2 internal
relays
to
control TWO
(2) access
control devices
like a vehicular
gate operator
and a
pedestrian gate
or door:
Address 001
and 002.

RS-485 Devices (Relays 3 - 8) connected to 2nd 1812 if desired (2nd 1812’s SW2 term. switch is ON).

RS-485 Devices (Relays 3 - 8) connected to 3rd 1812 if desired (3rd 1812’s SW2 term. switch is ON).

RS-485 Devices (Relays 3 - 8) connected to 4th 1812 if desired (4th 1812’s SW2 term. switch is ON).

RS-485 Devices (Relays 3 - 8) connected to 5th 1812 if desired (5th 1812’s SW2 term. switch is ON).

RS-485 Devices (Relays 3 - 8) connected to 2nd 1812 if desired (2nd 1812’s SW2 term. switch is ON).

RS-485 Devices (Relays 3 - 8) connected to 3rd 1812 if desired (3rd 1812’s SW2 term. switch is ON).

RS-485 Devices (Relays 3 - 8) connected to 4th 1812 if desired (4th 1812’s SW2 term. switch is ON).

RS-485 Devices (Relays 3 - 8) connected to 5th 1812 if desired (5th 1812’s SW2 term. switch is ON).

1

CENTRAL

OFFICE

EARTH

GND

PHONE

IN

PHONE

OUT

HOME

2

3

4

5

6

7

8

SW1

ENTRY

BY-PASS

1875-010

Maximum of 6 RS-485 Devices “Daisy Chain” per 1812

OFF

Address

003

Term Sw

OFF

Address

004

Term Sw

OFF

Address

005

Term Sw

OFF

Address

006

Term Sw

OFF

Address

007

Term Sw

Terminated

End Device

ON

Address

008

Term Sw

Telephone Mode -

Sample of Multiple 1812 Configuration Connection

Intercom Mode -

Sample of Multiple 1812 Configuration Connection

Phone Out

Phone Out

Phone In

Phone Out

Relay 3

Relay 2

Relay 1

Relay 2

Relay 1

Relay 2

Relay 1

Relay 2

Relay 1

Relay 2

Relay 1

Relay 4

Relay 5

Relay 6

Relay 7

Relay 8

Phone In

Phone Out

Phone In

Phone Out

Phone In

Phone In

Phone In

Phone Out

By-Pass Board

77

8

9

4

5

6

0

1st 1812

Phone Mode

Unique Master Code

2nd 1812

Phone Mode

Unique Master Code

3rd 1812

Phone Mode

Unique Master Code

4th 1812

Phone Mode

Unique Master Code

5th 1812

Phone Mode

Unique Master Code

7

8

9

4

5

6

0

7

8

9

4

5

6

0

7

8

9

4

5

6

0

7

8

9

4

5

6

1

2

3

0

11

2222

33

Homeowner’s

Phone

Note: Any Keypad, Cardreader or RF Receiver daisy chain sequence allowed. Each
RS-485 device will control 1 “Normally Open” OR “Normally Close” access control
device. ALL RS-485 devices must be powered from their own power source.

Phone
Company

Internet

OR

Fiber / V

olP

Device

Maximum of 6 RS-485 Devices “Daisy Chain” per 1812

OFF

Address

003

Term Sw

OFF

Address

004

Term Sw

OFF

Address

005

Term Sw

OFF

Address

006

Term Sw

OFF

Address

007

Term Sw

Terminated

End Device

ON

Address

008

Term Sw

Relay 3

Relay 4

Relay 5

Relay 6

Relay 7

Relay 8

Note: Any Keypad, Cardreader or RF Receiver daisy chain sequence allowed. Each
RS-485 device will control 1 “Normally Open” OR “Normally Close” access control
device. ALL RS-485 devices must be powered from their own power source.

Phone Out

Phone Out

Phone In

Phone In

1st 1812

Phone Mode

Unique Master Code

2nd 1812

Phone Mode

Unique Master Code

3rd 1812

Phone Mode

Unique Master Code

4th 1812

Phone Mode

Unique Master Code

5th 1812

INTERCOM MODE

Unique Master Code

Phone Out

Phone Out

Phone In

Phone In

Phone Out

Homeowner’s

Phone

7

8

9

4

5

6

0

7

8

9

4

5

6

0

7

8

9

4

5

6

0

7

8

9

4

5

6

0

7

8

9

4

5

6

0

Each 1812 has
2 internal
relays
to
control TWO
(2) access
control devices
like a vehicular
gate operator
and a
pedestrian gate
or door:
Address 001
and 002.

ON

SW2