Before proceeding with any of the programming steps in this section, install the 1812 Management software on the computer
(PC ONLY) that will be used
for this purpose. Be sure that the computer has a network card installed, or a modem installed in it
(or connected to it) depending on which connection method will be used. Once the software is installed and the 1812 is
connected, refer to the software programming steps and help screen instructions to proceed with the programming steps in this
section. The system keypad may be used to program the computer’s network setup in this section but can be a little tedious to
use.
Be sure that SW1 is in the ON position (MODEM/TCP ENB) on the Access Plus Interface Board.

2.3 Programming the Network Setup for a Computer

Reboot Note: If a programming step calls for a reboot, follow the programming steps in 2.3.1. If you are performing several
programming steps that call for a reboot, complete ALL of those steps first, then perform the reboot sequence in 2.3.1.

2.3.1 Enable / Disable TCP / IP Support - System Reboot

Factory setting is: 0 (TCP / IP Disabled)

This programming sequence enables or disables the support for TCP / IP. It will also cause an automatic reboot of the 1812
two seconds after the programming sequence is completed. For this reason, perform this step after all other network setup
programming sequences have been completed (2.3.2 through 2.3.5) or whenever an individual network programming step
is performed.

Once the 1812 is connected, the green LED on the RJ-45 jack on the interface board should light indicating that a good wire
connection has been made (See illustration above). The LAN DOWN LED should go off after a few seconds if all previous
programming steps have been completed and programmed successfully.

1. Press

*

5 0 and enter the MASTER CODE. [

*

5 0 _ _ _ _ (beep)]

2. Press 0

*

to disable TCP / IP OR press 1

*

to enable TCP / IP. [ _

*

(beep)]

3. The system will reboot automatically.

2.3.2 Set the 1812 IP Address

(reboot required)

Factory setting is: 192.168.001.030

This must be set to the same address that was programmed in the software. A valid value for any of the three digit fields in
this sequence is 000 to 255. (See pages 23 and 24 for network configurations and addresses)
All 3 digits MUST be entered in each field between dots, for example: 192.168.1.30 must be entered as 192.168.001.030

1. Press

*

5 1 and enter the MASTER CODE. [

*

5 1 _ _ _ _ (beep)]

2. Enter the IP address. Use the

*

key to enter the “dot”.

[ _ _ _

*

(beep) _ _ _

*

(beep) _ _ _

*

(beep) _ _ _

*

(beep)]

3. Press 0 # TOGETHER to end. [0 # (beeeeeep)]

77

8

9

4

5

6

0

System Keypad

7

8

9

4

5

6

0

System Keypad

Important Note: The 1812 will prompt you with short tones (beep) when each programming step has been correctly keyed
in and with a long tone (beeeeeep) when all of the programming steps have been successfully completed in the sequence.

ON

ON

MODEM / TCP ENB

1972-010

SW1

SW2

1
2
3
4
5
6
7
8

J1

J4

RJ-45

Jack

(Cat5)

LAN DOWN

J1

J1

J1

J1

J1

J1

J1

1

1

LAN

CONNECTION

Cat5 Cable

DATA TRANSMIT

BAD DNS

TERMINATION

RS-485 RX

PHONE LINE

IN USE

Advertising