Fulton Thermal Corp.*SteamPac Unfired Steam Generators Manual* Version 2010-0201

Page 13

Section 2 – Installation

1.

Introduction

a) This manual is provided as a guide to the correct operation and maintenance of your

unfired steam generator, and should be permanently available to the staff responsible for

the operation and maintenance of the unfired steam generator. These instructions must

not be considered as a complete code of practice, nor should they replace existing codes

or standards that may be applicable.

b) In the event that you require after sales service, Fulton Thermal Corporation has a

complete staff of field service technicians, and spare parts are available direct from the

factory. Should you require additional information or assistance on the operation and

maintenance of your unfired steam generator, please contact the Fulton service

department at (315) 298-7148 or contact your local Fulton Representative.

2. Placement

a) Proper placement of your unfired steam generator is essential. Attention paid to the

following points will save a great deal of difficulty in the future. Correct placement is the

first step to trouble free installation, operation and maintenance.

3. Transport

a) Fulton SteamPacs are skid mounted. Rollers should be placed beneath the frame of the

skid or the fork lift holes in the bottom of the skid may be utilized for positioning in the

installation area.

4. Location

1. Authorities with jurisdiction over any national, local or insurance codes should be

consulted prior to installation to assure compliance.

2. The unfired steam generator should be located as close as possible to the steam users in

order to keep condensation & pressure drop to a minimum.

3. A level, hard surface of non-combustible material is required as a suitable base for

mounting the unit. It is suggested that a 4” containment curb be installed completely

around the unit. In the event of a spill of thermal fluid, the curb will help contain the fluid.

5. Access

1. Access around the unfired steam generator should be provided to facilitate maintenance.

Place the SteamPac with clearances to unprotected combustible materials including

plaster or combustible supports not less than the clearances listed in the table below.