F are flexitallic spiral wound – Fulton Ancillary Equipment SteamPac Unfired Steam Generators User Manual

Page 26

Advertising
background image

Fulton Thermal Corp.*SteamPac Unfired Steam Generators Manual* Version 2010-0201

Page 26

Standard gaskets supplied by Fulton for operating temperatures above 650

o

F are

Flexitallic Spiral Wound.

Recommended Loads for Flexitallic Spiral Wound Class 150# Gaskets

SAE Grade 5 Bolts (typical) or Equal

Nominal Flange Size

Inches

Number of Bolts

Diameter of Bolts

Inches

Preferred Torque

Required per Bolt

Ft-Lbs.

1/2 4 1/2 45
3/4 4 1/2 45

1 4 1/2

45

1 ¼

4

1/2

45

1 ½

4

1/2

45

2 4 5/8

90

2 ½

4

5/8

90

3 4 5/8

90

3 ½

8

5/8

90

4 8 5/8

90

5 8 3/4

150

6 8 3/4

150

8 8 3/4

150

10 12 7/8 240

Recommended Loads for Flexitallic Spiral Wound Class 300# Gaskets

SAE Grade 5 Bolts (typical) or Equal

Nominal Flange Size

Inches

Number of Bolts

Diameter of Bolts

Inches

Preferred Torque

Required per Bolt

Ft-Lbs.

1/2 4 1/2 45
3/4 4 5/8

90

1 4 5/8

90

1 ¼

4

5/8

90

1 ½

4

3/4

150

2 8 5/8

90

2 ½

8

3/4

150

3 8 3/4

150

3 ½

8

3/4

150

4 8 3/4

150

5 8 3/4

150

6 12 3/4

150

8 12 7/8

240

10 16 1 368


Advertising