9. Troubleshooting

a) The following troubleshooting guide will assist in the diagnosis and correction of minor

field problems. In any case requiring additional assistance, contact your local authorized

Fulton Representative.

b) Feedwater

Pump

1. Problem:

Pump rotates freely but does not pump.

Check:

1. Excessive feed water temperature (normal maximum

180°F) will result in flashing at

pump inlet. This is usually caused by leaky

check valve between pump and boiler or

failure of steam traps to close tightly. Repair

or replace defective equipment at once

before causing damage to pump.

2. Obstruction in suction line. This can be determined by a

visual check or installing a

compound gauge (reading vacuum and pressure) in the

pump suction line close to the pump. An unrestricted line

will produce a pressure reading on the gauge of

approximately 1 PSIG while the pump is running. A

vacuum reading on the gauge indicates an obstruction,

which must be eliminated. Be sure to remove strainer

basket, scrub clean and reinstall.

3. Motor not up to rated speed. Check speed with

tachometer.

4. Wrong direction of rotation. Check arrow on pump

casing.

5. Broken pump shaft. Check shaft at both ends.

2. Problem:

Pump vibrates or is very noisy.

Check:

1. Misalignment of pump and motor. Check coupling and

piping strain.

2. Bent or broken shaft.

3. Pump impeller binding. Check for foreign

matter in pump, bent impeller, or mineral

deposits on impeller, channel ring or spacer. If mineral