Specifications and dimensions, Vertical steampacs – Fulton Ancillary Equipment SteamPac Unfired Steam Generators User Manual

Page 72

Advertising
background image

Fulton Thermal Corp.*SteamPac Unfired Steam Generators Manual* Version 2010-0201

Page 72

Specifications and Dimensions

Vertical SteamPacs

Specifications – Fulton Vertical SteamPacs from 10 to 100 HP

Models FT

010X

015X

020X

030X

040X

050X

075X

100X

Steam Output*

LB/HR

KG/HR

345

157

517

235

690

313

1,035

470

1,380

626

1,725

783

2,587

1,174

3,450

1,565

Input

BTU/HR (1000)

KCAL/HR (1000)

335

84

502

126

669

169

1,017

256

1,339

337

1,674

422

2,678

675

3,347

843

Flow Rate

GPM

M3/HR

23

5.2

35

8

46

10.5

69

16

92

21

114

26

171

39

228

52

*From and at 212

o

F (100

o

C). Steam Output is based in a minimum thermal fluid temperature of 425

o

F (218

o

C)

Dimensions – Fulton Horizontal SteamPacs from 10 to 100 HP

Models FT

010X

015X

020X

030X

040X

050X

075X

100X

A. Width

IN

MM

84

2,134

72

1,829

92

2,337

92

2,337

92

2,337

92

2,337

92

2,337

92

2,337

B. Length

IN

MM

72

1,829

84

2,134

72

1,829

72

1,829

72

1,829

72

1,829

92

2,337

92

2,337

C. Height

IN

MM

125

3,3175

125

3,3175

125

3,3175

125

3,3175

143

3,632

143

3,632

169

4,93

169

4,293

All dimensions are based on 550oF thermal fluid temperature and are subject to change based on

specific customer requirements. Vertical SteamPac dimensions include feedwater tank and blowdown separator.

All SteamPac accessories including feedwater tanks, feedwater pumps, blowdown separators,

chemical feed and water softeners are available from Fulton.

Advertising