6 optional hardware and software -1, 7 calibration and zero/span checks -1 – Teledyne 6400A - Sulfur dioxide analyzer User Manual
Page 4

TAI Model 6400A SO
2
Analyzer Operator Manual, 02164, Rev. G
ii
6 OPTIONAL HARDWARE AND SOFTWARE............................................ 6-1
6.1
R
ACK
M
OUNT
O
PTIONS
.............................................................................................. 6-1
6.2
Z
ERO
/S
PAN
V
ALVES
................................................................................................... 6-1
6.3
I
NTERNAL
Z
ERO
/S
PAN
(IZS)........................................................................................ 6-3
6.4
A
UTOCAL
-
S
ETUP OF
IZS
AND
Z
ERO
/S
PAN
V
ALVES
...................................................... 6-3
6.5
P
ERMEATION
T
UBE
(
USED WITH
IZS
OPTION
) ................................................................ 6-6
6.6
4-20
M
A,
C
URRENT
L
OOP
O
UTPUT
.............................................................................. 6-9
6.7
S
TATUS
O
UTPUT
........................................................................................................ 6-9
6.8
RS-232
I
NTERFACE
.................................................................................................. 6-10
6.8.1 Setting Up the RS-232 Interface ...................................................................... 6-10
6.8.2 Command Summary........................................................................................ 6-13
6.8.3 TEST Commands and Messages .................................................................... 6-17
6.8.4 WARNING Commands And Messages ........................................................... 6-18
6.8.5 CALIBRATION Commands and Messages ..................................................... 6-19
6.8.6 DIAGNOSTIC Commands and Messages....................................................... 6-20
6.8.7 DAS Commands and Reports ......................................................................... 6-21
6.8.8 VARIABLES Commands and Messages ......................................................... 6-24
7 CALIBRATION AND ZERO/SPAN CHECKS ........................................... 7-1
7.1
M
ANUAL
Z
ERO
/S
PAN
C
HECK OR
C
ALIBRATION THROUGH THE
S
AMPLE
P
ORT
.................. 7-4
7.2
M
ANUAL
Z
ERO
/S
PAN
C
HECK OR
C
ALIBRATION WITH
Z
ERO
/S
PAN
V
ALVES
O
PTION
........... 7-6
7.3
M
ANUAL
Z
ERO
/S
PAN
C
HECK WITH
IZS
O
PTION
............................................................ 7-7
7.4
A
UTOMATIC
Z
ERO
/S
PAN
C
HECK
.................................................................................. 7-7
7.5
A
UTOMATIC
Z
ERO
/S
PAN
C
ALIBRATION
......................................................................... 7-7
7.6
C
ALIBRATE ON
SO
2
P
ERMEATION
T
UBE
........................................................................ 7-8
7.7
U
SE OF
IZS
OR
Z
ERO
/S
PAN
V
ALVES WITH
R
EMOTE
C
ONTACT
C
LOSURE
......................... 7-8
7.8
EPA
P
ROTOCOL
C
ALIBRATION
.................................................................................... 7-9
7.8.1 Calibration of Equipment ................................................................................... 7-9
7.8.2 Calibration Gas Sources.................................................................................. 7-10
7.8.3 Data Recording Device.................................................................................... 7-12
7.8.4 Dynamic Multipoint Span Calibration ............................................................... 7-12
7.8.5 SO
2
Calibration Procedure............................................................................... 7-13
7.8.6 Calibration Frequency...................................................................................... 7-19
7.8.7 Other Quality Assurance Procedures .............................................................. 7-19
7.8.8 Summary of Quality Assurance Checks .......................................................... 7-21
7.8.9 ZERO and SPAN Checks ................................................................................ 7-22
7.8.10 Recommended Standards for Establishing Traceability ................................ 7-23
7.9
S
PECIAL
C
ALIBRATION
R
EQUIREMENTS FOR
D
UAL
R
ANGE OR
A
UTO
R
ANGE
.................. 7-24
7.10
C
ALIBRATION
Q
UALITY
............................................................................................ 7-25
7.11
R
EFERENCES
......................................................................................................... 7-26