Interconnection wiring, Dip (address) switch setup, sscs, Intalogix – Fairbanks MATRIX SCALE HIGHWAY SCALE SYSTEM User Manual
Page 27: Systems installation, continued, Always off
                                    Advertising
                                    
                                        
                                    
                                
                                 
Section 4: Wiring
11/12
27
51182 Rev. 2
Intalogix
™
Systems Installation, Continued
Load Cell Wiring Designations
Color
Description
Black
(
─) Excitation
Green
(+) Excitation
Red
(
─) Signal
White
(+) Signal
Yellow
Shield
Interconnection Wiring
TB3 or TB4 in SSC
Function
17246 Cable
1
(-) 8.0 volts
Black
2
(+) 8.0 volts
Green
5
DC Return
Blue
6
Shield
Shield
7
RS-485 (+)
White
8
RS-485 (-)
Red
Dip (Address) Switch Setup, SSCs
• In each of the SSC
boxes, there is a ten 
(10) position dip switch 
labeled 
S1
.
─
This switch is used 
to identify the 
section in a binary 
code. 
• The switches must be
set properly for the 
scale to operate. 
NOTE:
Switches 1, 2, 3, 4, are
always OFF
.
SW 1 position 5 setting:
OFF = 350
Ω load cells
ON = 700/1000
Ω load cells