Section 4: Wiring

11/12

32

51182 Rev. 2

Indicator to Pit Power Supply Cable Connection, continued

• Wire the PPS to the Instrument.

Run the Home-Run Cable from the PPS – TB1 to the Instrument's TB1.

Shields are used for DC Return and MUST BE CONNECTED.

Connect the wires as shown in this chart.

TB1 PPS

TB1 Inst

17246 Cable

Description

1

1

Black

28 volts, AC

2

2

Green

AC Return

3

3

Blue

20 Volts, DC

4

4

Orange

Enable

6

6

Shield

Shield/DC Return

7

7

White

Transmit

8

8

Red

Receive

Advertising