Indicator to Pit Power Supply Cable Connection, continued
• Wire the PPS to the Instrument.
─
Run the Home-Run Cable from the PPS – TB1 to the Instrument's TB1.
─
Shields are used for DC Return and MUST BE CONNECTED.
Connect the wires as shown in this chart.
TB1 PPS
TB1 Inst
17246 Cable
Description
1
1
Black
28 volts, AC
2
2
Green
AC Return
3
3
Blue
20 Volts, DC
4
4
Orange
Enable
6
6
Shield
Shield/DC Return
7
7
White
Transmit
8
8
Red
Receive