Specifications, Electrical, Pneumatic – Ransburg PulseTrack2 A11515-XXXXX User Manual

Page 12: General, Temperature / humidity probe, Environmental / physical

Advertising
background image

SPECIFICATIONS

Operating

Temperature:

0°C to 50°C

Storage

Temperature:

-20°C to 85°C

Humidity:

0 to 95% non-condensing

Size:

20" H x 16" W x 8" D

(50.8 cm X 40.6 cm X 20.3 cm)

Weight:

52 lbs. (23.6 kg)

Electrical

AC Input:

A11515-XX0XX Models

100-120 VAC, 50/60 Hz

2.1 A rms

Fused at 3 Amps

A11515-XX1XX Models

200-240 VAC, 50/60 Hz

1.1 A rms

Fused at 1.5 Amps

Analog Inputs:

Remote Speed Setpoint

0-10 VDC or 4-20mA

Switch Selectable

Temp./Humidity Inputs

4-20mA

250 ft. (76.2m) maximum

cable length

Analog Outputs:

Speed Feedback

0-10 VDC or 4-20mA

Switch Selectable

Discreet Inputs:

Master Enable, Master

Reset, Rotator Enable

Sourced 24 VDC @ 2.3mA

Active Low - connect input

to ground to activate

Discreet

Outputs:

Temperature/Humidity,

Master Overspeed, Master

Underspeed, Master Loss

of Feedback, Master Fault,

Rotator Active, Rotator

Fault, Brake Control Active

High - put out 24 VDC when

active, 0.25A maximum per

output

Pneumatic

Inputs

Supply Air:

1/4" ID x 3/8" OD

110 psi (7.6 bar) maximum,

operating

80 psi (5.5 bar) minimum,

operating

40 micron filtration

Pressure Switches

(Enable Inputs):

15 psi (1.03 bar) minimum

to

activate

150 psi (10.3 bar) maximum

Outputs

Control Outputs*:

0.106" ID by 5/32" OD

100 ft. (30.5m) maximum

length to volume booster

Brake Control*:

0.170" ID x 1/4" OD

100 ft. (30.5m) maximum

length to brake valve

assembly

Brake Supply*:

1/4" ID x 3/8" OD

100 psi maximum

100 ft. (30.5m) maximum

length from brake valve

assembly

to

rotator

General

Fiber Optic

Cable:

Maximum length is 150 ft.

(45.7m)

Temperature / Humidity Probe

Temperature

Range:

0-100°C (32-212°F)

Accuracy:

± 0.6°C (± 1°F)

Repeatability:

± 0.3°C (± 0.5°F)

Humidity

Range:

3-95% RH

Accuracy (@ 72°F):

± 2.5% from 20% to 80%

± 3.1% <20%, >80%

Drift:

± 0.1% / °F

Repeatability:

± 1% RH

* Longer tubing lengths may be acceptable de-

pending on overall total lengths of pilot signals

and supply signals and the specific application.

However, longer lengths may degrade overall

speed control performance.

Environmental / Physical

Advertising