Atomizer card controls – Ransburg PulseTrack2 A11515-XXXXX User Manual

Page 32

Advertising
background image

Figure 12: Front Panel Operating Controls

ATOMIZER CARD

CONTROLS

(See Figure 13)

Atomizer Speed Display

This two digit display indicates rotator speed in

rpm x 1000 (krpm) during normal speed control

operation. During fault conditions a two digit

fault code is displayed to indicate what fault has

occurred.

Speed Select Thumbwheel Switch

This switch is used in local mode to manually enter

the speed control setpoint in thousands of rpms

(krpm). Press the + or - switch buttons to incre-

ment or decrement the desired digit. After setting

the desired values, press the Speed Enter button

to confirm the new setpoint. If the setpoint is set

higher than the maximum allowable rotator speed,

“In” (invalid request) will flash in the speed display

until the setpoint is reduced below the maximum.

Advertising