ELECTRICAL I/O

(See Table 5)

Electrical I/O terminals are available from a

breakout board inside the PulseTrack 2 control

Panel (see Figures 6 and 7). For maximum noise

immunity all electrical I/O should be run in cable

having a foil shield with an overall braided shield.

Special noise reduction connectors have been

provided at the top of the PulseTrack 2 control

panel for routing of all electrical I/O (see Figure

8). Signals specific to an individual rotator can be

routed through that rotator's ATM connector, while

common signals can be routed through the SYS

connector. To make electrical I/O connections

using these connectors, perform the following:

1. Remove the cable grommet hardware from the

desired connector (see Figure 9A).

2. Route desired length of cable through connector

housing and mark 1" span of cable that passes

through connector housing as shown in Figure

9B.

3. Remove cable and strip marked 1" section to

the cable braid.

4. Slide the cable grommet hardware onto the

cable in the order shown in Figure 9A.

5. Route the cable back through the cable housing

and make the appropriate I/O terminal connections

(see Table 5).

6. Tighten the cable grommet ensuring the grom-

met spring makes 360° contact with the exposed

cable braid.

7. For maximum noise immunity, connect the braid

of the cable to earth ground at the end opposite

the control panel.